Model | AirJet12 | AirJet12+ | AirJet24 | AirJet24+ |
---|---|---|---|---|
Nominal cooling capacity BTU/h | 3700* – 6100 | 6100* – 8800 | 5400* – 7400 | 7400* – 11400 |
Nominal cooling capacity W | 1080* – 1780 | 1780* – 2570 | 1580* – 2170 | 2179* – 3341 |
Power supply | 12V DC | 12V DC | 24V DC | 24V DC |
Full load amps FLA A | 50* – 65 | 65* – 85 | 39* – 44 | 44* – 49 |
Power input kW | 0,6* – 0,8 | 0,8* – 1,1 | 0,93* – 1 | 1* – 1,18 |
Refrigerant charge g | 230 | 230 | 240 | 240 |
Blower diameter mm | 80 | 80 | 100 | 100 |
Air flow mc/h | 500 | 500 | 580 – 660 | 660 – 750 |
Sea water connections mm | 18 | 18 | 18 | 18 |
Water flow l/min | 6 | 7,5 | 12 | 12 |
Compressor | scroll BLDC | scroll BLDC | scroll BLDC | scroll BLDC |
Wiring diameter mm | 10 | 10 | 10 | 10 |
Net weight kg | 17 | 17 | 18 | 18 |
Sizes self contained version LxDxH mm | 380x500x240 | 380x500x240 | 330x480x280 | 330x480x280 |
Sizes split version LxWxH mm | See images | See images | See images | See images |
*I dati si riferiscono alla performance dell’unità con accessorio opzionale parzializzazione 50%-100% The specifications are related to the performance of the unit with the optional accessory power shift 50%-100% |
AirJet 12 e AirJet 24 are the exclusive and innovative sea water cooled boat air conditioner directly powered in 12V or 24V (direct current) from the battery bank of your boat, without using a generator or an inverter.
AirJet 12/24 is a well designed and elegant product which offers the most simple and versatile installation. According to the volume available on board for its installation, it is possible to choose between the split arrangement or 2 self contained arrangements, horizontal or vertical. AirJet 12/24 is the ideal solution for cooling single cabins. The heart of this air conditioner is a semi-hermetic horizontal scroll compressor using an advanced brushless DC motor (BLCD) which allows the direct connection to the boat’s battery bank, also avoiding, through a dedicated program of the compressor control driver, the start – up peak.